Medical Spa MD is an active community of more than 5,000 plastic surgeons, dermatologists, & aesthetic physicians practicing cosmetic medicine. FREE Medical Spa Deals for Physicians & Medical Spas
About   l   Advertise   l   Press   l   Contact

Medical Spa MD RSS    Twitter     Facebook        LinkedIn      Subscribe via Email

Group Buy Botox from Medical Spa RX

From Our Partners

The very best bang for your buck cosmetic marketing!
Watch demo Frontdesk waiting room videos and DVDs.

Frontdesk Waiting Room Videos

Medical spa & laser clinic staff training manuals.

Medical Spa Staff Training Manuals
 
Medical Spa Classifieds
Medical Spa Jobs

Medical Spa MD is the primier physician community for clinicians in skin clinics, laser centers and medspas with thousands of physician members around the world.

Join Medical Spa MD

Not a member?

Thousands of physicians have already joined Medical Spa MD.

Bodysculpting & Liposuction > Comparative Study of Wavelengths for Laser Lipolysis

http://www.liebertonline.com/doi/abs/10.1089/pho.2008.2480

I have not read the full article as I am waiting on the print version but figured it might stimulate some discussion.

Abstract

Objective: This aim of this study was to evaluate the role of different wavelengths (920nm, 980nm, 1064nm, 1320nm, and 1440nm) in laser lipolysis. Background: Laser lipolysis is fast becoming a recognized technique for fat reduction. It has been demonstrated that (i) fat liquefaction is induced through a temperature elevation of the adipocyte cells, and (ii) fat volume reduction depends on total cumulative energy delivered at the treatment site. Materials and Methods: The optical coefficients and the total attenuation for fat tissue were determined in the 400–1500nm window. Numerical simulations were performed to estimate final fat reduction as a function of wavelength. Results: The penetration depth of wavelengths between 900 and 1320nm are largely similar, around 1.5mm. The only minor difference is at 1440nm, which is more absorbed by subcutaneous fat. The irreversibly damaged volume of tissue estimated by our numerical simulation is similar for wavelengths between 920 and 1320nm. We obtain a final volume of 4cm3 with 3750J delivered. Conclusion: With laser lipolysis, thermal elevation of a given volume can be obtained provided that the penetration depth remains in this nominal range. This explains why similar end results can be obtained using 920nm, 980nm, 1064nm, and 1320nm. Thermal build-up is the main factor behind adipocytolysis and skin contraction. Successful outcomes are dependent on the movement of the optical fiber inside the tissue and even and stable delivery of energy.

http://www.liebertonline.com/doi/abs/10.1089/pho.2008.2480

I have not read the full article as I am waiting on the print version but figured it might stimulate some discussion.

Abstract

Objective: This aim of this study was to evaluate the role of different wavelengths (920nm, 980nm, 1064nm, 1320nm, and 1440nm) in laser lipolysis. Background: Laser lipolysis is fast becoming a recognized technique for fat reduction. It has been demonstrated that (i) fat liquefaction is induced through a temperature elevation of the adipocyte cells, and (ii) fat volume reduction depends on total cumulative energy delivered at the treatment site. Materials and Methods: The optical coefficients and the total attenuation for fat tissue were determined in the 400–1500nm window. Numerical simulations were performed to estimate final fat reduction as a function of wavelength. Results: The penetration depth of wavelengths between 900 and 1320nm are largely similar, around 1.5mm. The only minor difference is at 1440nm, which is more absorbed by subcutaneous fat. The irreversibly damaged volume of tissue estimated by our numerical simulation is similar for wavelengths between 920 and 1320nm. We obtain a final volume of 4cm3 with 3750J delivered. Conclusion: With laser lipolysis, thermal elevation of a given volume can be obtained provided that the penetration depth remains in this nominal range. This explains why similar end results can be obtained using 920nm, 980nm, 1064nm, and 1320nm. Thermal build-up is the main factor behind adipocytolysis and skin contraction. Successful outcomes are dependent on the movement of the optical fiber inside the tissue and even and stable delivery of energy.

Medical spa information for, laser clinics, skin clinics, laser centers, PAs, medical esthetician, and doctors. MedSpa MD offers information about Thermage, IPL, used cosmetic lasers, Liposolve mesotherapy, Cutera Titan, Dysport, Botox, medspa franchises, laser hair removal, Palomar Starlux, training manuals, estheticians, tumescent liposuction, smartlipo, lipodissolve, PPC advertising, training, videos, webinars, seminars, conferences & more. Forums include discussions for plastic surgeons, dermatologists, businesses, advertising,legal,IPL & laser reviews, Thermage & Fraxel, esthetician, technicians, nurses, PAs & more.